Share Email Print
cover

Proceedings Paper

Optimizing source detector separation for an implantable perfusion and oxygenation sensor
Author(s): T. J. Akl; T. J. King; R. Long; J. S. Baba; M. J. McShane; M. N. Ericson; M. A. Wilson; G. L. Coté
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Each year thousands of patients are added to the waiting list for liver transplants. The first 7-10 days after transplant have proven to be the most critical in patient recovery and it is hypothesized that monitoring organ vital signals in this period can increase patient and graft survival rates. An implantable sensor to monitor the organ perfusion and oxygenation signals following surgery is being developed by our group. The sensor operates based on measuring diffuse reflection from three light emitting diodes (735, 805 and 940 nm). In this work the optimal source detector spacing to maximize oxygenation signal level is investigated for a portal vein model. Monte Carlo simulations provided signal levels and corresponding penetration depths as a function of separation between a point optical source and detector. The modeling results indicated a rapid decay in the optical signal with increasing distance. Through further analysis, it was found that there exists an optimal range of point source to detector spacing, between roughly 1 and 2 mm, in which the blood signal from the simulated portal vein was maximized. Overall, these results are being used to guide the placement and configuration of our probe for in vivo animal studies.

Paper Details

Date Published: 10 February 2011
PDF: 5 pages
Proc. SPIE 7906, Optical Diagnostics and Sensing XI: Toward Point-of-Care Diagnostics; and Design and Performance Validation of Phantoms Used in Conjunction with Optical Measurement of Tissue III, 790605 (10 February 2011); doi: 10.1117/12.875731
Show Author Affiliations
T. J. Akl, Texas A&M Univ. (United States)
T. J. King, Texas A&M Univ. (United States)
R. Long, Texas A&M Univ. (United States)
J. S. Baba, Oak Ridge National Lab. (United States)
M. J. McShane, Texas A&M Univ. (United States)
M. N. Ericson, Oak Ridge National Lab. (United States)
M. A. Wilson, Univ. of Pittsburgh (United States)
VA Pittsburgh Healthcare System (United States)
G. L. Coté, Texas A&M Univ. (United States)


Published in SPIE Proceedings Vol. 7906:
Optical Diagnostics and Sensing XI: Toward Point-of-Care Diagnostics; and Design and Performance Validation of Phantoms Used in Conjunction with Optical Measurement of Tissue III
Gerard L. Coté; Robert J. Nordstrom, Editor(s)

© SPIE. Terms of Use
Back to Top