Estimation of organ and effective dose to the patient during spinal surgery with a cone-beam O-arm system
Author(s): Marcus Söderberg; Kasim Abul-Kasim; Acke Ohlin; Mikael Gunnarsson
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

The purpose of this study was to estimate organ and effective dose to the patient during spinal surgery with a cone-beam O-arm system. The absorbed dose to radiosensitive organs and effective dose were calculated on mathematically simulated phantom corresponding to a 15-year-old patient using PCXMC 2.0. Radiation doses were calculated at every 15° of the x-ray tube projection angle at two regions: thoracic spine and lumbar spine. Two different scan settings were investigated: 120 kV/128 mAs (standard) and 80 kV/80 mAs (low-dose). The effect on effective dose by changing the number of simulated projection angles (24, 12 and 4) was investigated. Estimated effective dose with PCXMC was compared with calculated effective dose using conversion factors between dose length product (DLP) and effective dose. The highest absorbed doses were received by the breast, lungs (thoracic spine) and stomach (lumbar spine). The effective doses using standard settings were 5 times higher than those delivered with low-dose settings (2-3 scans: 7.9-12 mSv versus 1.5-2.4 mSv). There was no difference in estimated effective dose using 24 or 12 projection angles. Using 4 projection angles at every 90° was not enough to accurate simulate the x-ray tube rotating around the patient. Conversion factors between DLP and effective dose were determined. Our conclusion is that the O-arm has the potential to deliver high radiation doses and consequently there is a strong need to optimize the clinical scan protocols.

Paper Details

Date Published: 17 March 2011
PDF: 6 pages
Proc. SPIE 7961, Medical Imaging 2011: Physics of Medical Imaging, 79613G (17 March 2011); doi: 10.1117/12.873369
Show Author Affiliations
Marcus Söderberg, Skåne Univ. Hospital Malmö (Sweden)
Kasim Abul-Kasim, Skåne Univ. Hospital Malmö (Sweden)
Acke Ohlin, Skåne Univ. Hospital Malmö (Sweden)
Mikael Gunnarsson, Skåne Univ. Hospital Malmö (Sweden)


Published in SPIE Proceedings Vol. 7961:
Medical Imaging 2011: Physics of Medical Imaging
Norbert J. Pelc; Ehsan Samei; Robert M. Nishikawa, Editor(s)

© SPIE. Terms of Use
Back to Top