Theoretical studies of floating-reference method for NIR blood glucose sensing
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Non-invasive blood glucose monitoring using NIR light has been suffered from the variety of optical background that is mainly caused by the change of human body, such as the change of temperature, water concentration, and so on. In order to eliminate these internal influence and external interference a so called floating-reference method has been proposed to provide an internal reference. From the analysis of the diffuse reflectance spectrum, a position has been found where diffuse reflection of light is not sensitive to the glucose concentrations. Our previous work has proved the existence of reference position using diffusion equation. However, since glucose monitoring generally use the NIR light in region of 1000-2000nm, diffusion equation is not valid because of the high absorption coefficient and small source-detector separations. In this paper, steady-state high-order approximate model is used to further investigate the existence of the floating reference position in semi-infinite medium. Based on the analysis of different optical parameters on the impact of spatially resolved reflectance of light, we find that the existence of the floating-reference position is the result of the interaction of optical parameters. Comparing to the results of Monte Carlo simulation, the applicable region of diffusion approximation and higher-order approximation for the calculation of floating-reference position is discussed at the wavelength of 1000nm-1800nm, using the intralipid solution of different concentrations. The results indicate that when the reduced albedo is greater than 0.93, diffusion approximation results are more close to simulation results, otherwise the high order approximation is more applicable.

Paper Details

Date Published: 11 February 2011
PDF: 9 pages
Proc. SPIE 7906, Optical Diagnostics and Sensing XI: Toward Point-of-Care Diagnostics; and Design and Performance Validation of Phantoms Used in Conjunction with Optical Measurement of Tissue III, 79060W (11 February 2011); doi: 10.1117/12.872271
Show Author Affiliations
Zhenzhi Shi, Tianjin Univ. (China)
Yue Yang, Tianjin Univ. (China)
Huijuan Zhao, Tianjin Univ. (China)
Wenliang Chen, Tianjin Univ. (China)
Rong Liu, Tianjin Univ. (China)
Kexin Xu, Tianjin Univ. (China)


Published in SPIE Proceedings Vol. 7906:
Optical Diagnostics and Sensing XI: Toward Point-of-Care Diagnostics; and Design and Performance Validation of Phantoms Used in Conjunction with Optical Measurement of Tissue III
Gerard L. Coté; Robert J. Nordstrom, Editor(s)

© SPIE. Terms of Use
Back to Top