Share Email Print
cover

Proceedings Paper

Study on computer-aided alignment method of Cassegrain system
Author(s): Wang Bin; Jiang Shi Lei; Qiu Tian
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

To realize the fast, efficient alignment of Cassegrain system, the scheme of computer-aided alignment is proposed. The misalignment state of Cassegrain system was simulated in Zemax, corresponding relationship between the misalignments and Zernike polynomial coefficients is analyzed and the misalignment characteristics of Cassegrain system were summarized by Matlab. Finally, the alignment scheme is determined by analysis. In order to verify the scheme, the Cassegrain system was aligned according to the value which was calculated in accordance with the alignment scheme. The result demonstrates that the alignment scheme is feasible to Cassegrain system. Satisfactory results are achieved in applying the scheme of computer-aided alignment to the alignment of 1.2m and 1.8m telescopes.

Paper Details

Date Published: 14 October 2010
PDF: 6 pages
Proc. SPIE 7654, 5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Large Mirrors and Telescopes, 765405 (14 October 2010); doi: 10.1117/12.867978
Show Author Affiliations
Wang Bin, Institute of Optics and Electronics (China)
Jiang Shi Lei, Institute of Optics and Electronics (China)
Qiu Tian, Institute of Optics and Electronics (China)


Published in SPIE Proceedings Vol. 7654:
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Large Mirrors and Telescopes
Wenhan Jiang; Myung K. Cho; Fan Wu, Editor(s)