Share Email Print
cover

Proceedings Paper

A calibration method of monocular stereo vision system for on-machine measurement
Author(s): Zhongren Wang; Lijun Deng
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

A calibration method of movable monocular stereo vision measurement system for on-machine measurement was presented based on standard dimension. The physical model and mathematical model was established in view of perspective projection transformation. Structure parameters of this stereo vision system were determined using Levenberg-Marquardt algorithm. Experiment results show that this calibration method can achieve precise camera parameters and three dimensional space coordinates and can be employed conveniently in real industrial environment.

Paper Details

Date Published: 20 August 2010
PDF: 8 pages
Proc. SPIE 7820, International Conference on Image Processing and Pattern Recognition in Industrial Engineering, 78201K (20 August 2010); doi: 10.1117/12.866688
Show Author Affiliations
Zhongren Wang, Xiangfan Univ. (China)
Lijun Deng, Xiangfan Univ. (China)


Published in SPIE Proceedings Vol. 7820:
International Conference on Image Processing and Pattern Recognition in Industrial Engineering

© SPIE. Terms of Use