The paper describes a new magnetometer with Cs vapor in the spin exchange relaxation free (SERF) regime. Because cesium atom has a higher saturated vapor pressure than other alkali metallic atoms, so the magnetometer has required lower operated temperature. We have discussed the effect of different pumping intensities on the polarization and the pumping rate at 105°C in theory; and the result shows out the magnetometer will have maximum sensitivity when the pumping intensity is 52mW/cm2. Taking into account all relaxations including collision relaxations, diffusion relaxation and pumping relaxation from pump light, we find the relaxation rate will be about 6Hz for the cesium magnetometer with SERF.

Paper Details

Date Published: 11 October 2010
PDF: 7 pages
Proc. SPIE 7656, 5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, 76560W (11 October 2010); doi: 10.1117/12.866140
Show Author Affiliations
Junhai Zhang, Harbin Engineering Univ. (China)
Feng Wang, Harbin Engineering Univ. (China)
Heilongjiang Institute of Science and Technology (China)
Jiuxing Li, Harbin Engineering Univ. (China)
Weimin Sun, Harbin Engineering Univ. (China)


Published in SPIE Proceedings Vol. 7656:
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment

© SPIE. Terms of Use
Back to Top