Share Email Print
cover

Proceedings Paper

Evaluating calibrations of normal incident pyrheliometers
Author(s): Frank Vignola; Fuding Lin
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

When an Eppley Normal Incident Pyrheliometer is calibrated against an Eppley Hickey Frieden Absolute Cavity Radiometer, the instrument systematically deviates from the absolute cavity readings. The reason for this deviation is not understood. Comparisons are made between one pyrheliometer and an absolute cavity radiometer on selected clear days over a period of 8 months in Eugene, Oregon. The ratios of the readings from the two instruments are correlated against wind speed, pressure, temperature, relative humidity, beam intensity, and zenith angle to determine if any of these parameters statistically influence the calibration process. Wind speed, pressure, beam intensity, and air mass are shown to be statistically significant factors in determining the responsivity of the normal incident pyrheliometer. The results of these tests are evaluated and discussed. Use of air mass instead of zenith angle is proposed for calibration reports.

Paper Details

Date Published: 19 August 2010
PDF: 8 pages
Proc. SPIE 7773, Reliability of Photovoltaic Cells, Modules, Components, and Systems III, 77730H (19 August 2010); doi: 10.1117/12.861344
Show Author Affiliations
Frank Vignola, Univ. of Oregon (United States)
Fuding Lin, Univ. of Oregon (United States)


Published in SPIE Proceedings Vol. 7773:
Reliability of Photovoltaic Cells, Modules, Components, and Systems III
Neelkanth G. Dhere; John H. Wohlgemuth; Kevin Lynn, Editor(s)

© SPIE. Terms of Use
Back to Top