Share Email Print
cover

Proceedings Paper

Performance of the SITP 35K two-stage Stirling cryocooler
Author(s): Dongyu Liu; Ao Li; Shanshan Li; Yinong Wu
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

This paper presents the design, development, optimization experiment and performance of the SITP two-stage Stirling cryocooler. The geometry size of the cooler, especially the diameter and length of the regenerator were analyzed. Operating parameters by experiments were optimized to maximize the second stage cooling performance. In the test the cooler was operated at various drive frequency, phase shift between displacer and piston, fill pressure. The experimental results indicate that the cryocooler has a higher efficiency with a performance of 0.85W at 35K with a compressor input power of 56W at a phase shift of 65°, an operating frequency of 40Hz, 1MPa fill pressure.

Paper Details

Date Published: 4 May 2010
PDF: 6 pages
Proc. SPIE 7660, Infrared Technology and Applications XXXVI, 76602P (4 May 2010); doi: 10.1117/12.849863
Show Author Affiliations
Dongyu Liu, Shanghai Institute of Technical Physics (China)
Ao Li, Shanghai Institute of Technical Physics (China)
Shanshan Li, Shanghai Institute of Technical Physics (China)
Yinong Wu, Shanghai Institute of Technical Physics (China)


Published in SPIE Proceedings Vol. 7660:
Infrared Technology and Applications XXXVI
Bjørn F. Andresen; Gabor F. Fulop; Paul R. Norton, Editor(s)

© SPIE. Terms of Use
Back to Top