Share Email Print
cover

Proceedings Paper

A MEMS based measurement system for structure health monitoring applications
Author(s): Soeren Majcherek; Soeren Hirsch; Bertram Schmidt
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

The structure health monitoring becomes more and more important to increase the reliability of important assemblies and structures. Therefore, a silicon test chip was developed to analyse acting mechanical loads at critical structure locations. Standard MEMS technologies are used for manufacturing an array structure of stress sensitive elements. Up to 16 sections with each 6 stress sensitive resistors can be measured continuously by one measurement hardware unit. Interpretation and correction of the measured raw data is performed in proper computer software. The whole system can be utilized as a self-sufficient measurement chain for structure health monitoring.

Paper Details

Date Published: 9 April 2010
PDF: 9 pages
Proc. SPIE 7650, Health Monitoring of Structural and Biological Systems 2010, 76501R (9 April 2010); doi: 10.1117/12.846736
Show Author Affiliations
Soeren Majcherek, Otto-von-Guericke-Univ. Magdeburg (Germany)
Soeren Hirsch, Otto-von-Guericke-Univ. Magdeburg (Germany)
Bertram Schmidt, Otto-von-Guericke-Univ. Magdeburg (Germany)


Published in SPIE Proceedings Vol. 7650:
Health Monitoring of Structural and Biological Systems 2010
Tribikram Kundu, Editor(s)

© SPIE. Terms of Use
Back to Top