In order to obtain a definitive diagnosis of prostate cancer, over one million men undergo prostate biopsies every year. Currently, biopsies are performed under two-dimensional (2D) transrectal ultrasound (TRUS) guidance with manual stabilization of a hand-held end- or side-firing transducer probe. With this method, it is challenging to precisely guide a needle to its target due to a potentially unstable ultrasound probe and limited anatomic information, and it is impossible to obtain a 3D record of biopsy locations. We have developed a mechanically-stabilized, 3-dimensional (3D) TRUSguided prostate biopsy system, which provides additional anatomic information and permits a 3D record of biopsies. A critical step in this system's performance is the registration of 3D-TRUS images obtained during the procedure, which compensates for intra-session motion and deformation of the prostate. We evaluated the accuracy and variability of surface-based 3D-TRUS to 3D-TRUS rigid and non-rigid registration by measuring the target registration (TRE) error as the post-registration misalignment of manually marked, corresponding, intrinsic fiducials. We also measured the fiducial localization error (FLE), to measure its contribution to the TRE. Our results yielded mean TRE values of 2.13 mm and 2.09 mm for rigid and non-rigid techniques, respectively. Our FLE of 0.21 mm did not dominate the overall TRE. These results compare favorably with a clinical need for a TRE of less than 2.5 mm.

Paper Details

Date Published: 24 February 2010
PDF: 8 pages
Proc. SPIE 7625, Medical Imaging 2010: Visualization, Image-Guided Procedures, and Modeling, 762516 (24 February 2010); doi: 10.1117/12.844332
Show Author Affiliations
V. Karnik, Robarts Research Institute (Canada)
A. Fenster, Robarts Research Institute (Canada)
The Univ. of Western Ontario (Canada)
J. Bax, Robarts Research Institute (Canada)
D. Cool, Robarts Research Institute (Canada)
The Univ. of Western Ontario (Canada)
L. Gardi, Robarts Research Institute (Canada)
I. Gyacskov, Robarts Research Institute (Canada)
C. Romagnoli, Robarts Research Institute (Canada)
A. D. Ward, Robarts Research Institute (Canada)


Published in SPIE Proceedings Vol. 7625:
Medical Imaging 2010: Visualization, Image-Guided Procedures, and Modeling
Kenneth H. Wong; Michael I. Miga, Editor(s)

© SPIE. Terms of Use
Back to Top