Share Email Print
cover

Proceedings Paper

Automatic lumen segmentation from intravascular OCT images
Author(s): Rafik Bourezak; Guy Lamouche; Farida Cheriet
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

In the last decade intravascular optical coherence tomography has known a tremendous progress. Its high resolution (5- 10μm) allows coronary plaque characterization, vulnerable plaque assessment, and the guidance of intravascular interventions. However, one intravascular OCT sequence contains hundreds of frames, and their interpretation requires a lot of time and energy. Therefore, there is a strong need for automated segmentation algorithms to process this large amount of data. In this article, we present an automated algorithm to extract lumen contours from images obtained with intravascular Optical Coherence Tomography (OCT). Unlike existing methods, our algorithm requires no post- or preprocessing of the image. First, a sliding window is passed on every A-scan to locate the artery tissue, this location being determined from the largest distribution of the grey level values. Once all the tissue is extracted from the image, every segmented A-scan is binarized separately. For a single A-scan, the level of amplitude often varies strongly across the tissue. A global threshold would cause low amplitude parts of the tissue to be considered as belonging to the background. Our solution is to determine local thresholds for every A-scan. That is, instead of having a single global threshold, we allow the threshold itself to smoothly vary across the image. Subsequently, on the binarized image the Prewitt mask is moved from the detected tissue position toward the probe to segment the lumen. The proposed method has been validated qualitatively on images acquired under different conditions without changing any parameter of the algorithm. Experimental results show that the proposed method is accurate and robust to extract lumen borders.

Paper Details

Date Published: 9 March 2010
PDF: 5 pages
Proc. SPIE 7624, Medical Imaging 2010: Computer-Aided Diagnosis, 76242R (9 March 2010); doi: 10.1117/12.844316
Show Author Affiliations
Rafik Bourezak, Ecole Polytechnique de Montréal (Canada)
National Research Council Canada (Canada)
Guy Lamouche, National Research Council Canada (Canada)
Ecole Polytechnique de Montréal (Canada)
Farida Cheriet, Ecole Polytechnique de Montréal (Canada)


Published in SPIE Proceedings Vol. 7624:
Medical Imaging 2010: Computer-Aided Diagnosis
Nico Karssemeijer; Ronald M. Summers, Editor(s)

© SPIE. Terms of Use
Back to Top