
Proceedings Paper
Amorphous silicon p-i-n photodetector with Frisch grid for high-speed medical imagingFormat | Member Price | Non-Member Price |
---|---|---|
$14.40 | $18.00 |
![]() |
GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. | Check Access |
Paper Abstract
In indirect digital x-ray detectors, photodetectors such as hydrogenated amorphous silicon (a-Si:H) p-i-n photodetectors
are used to convert the optical photons generated by the scintillating material to collectible electron-hole
pairs. A problem that arises during the collection of the charges is that the mobility and lifetime of both types
of carriers (electrons and holes) differ. In a-Si:H, the mobility of holes is much lower than that of electrons which
leads to depth-dependent signal variations and causes the charge collection time to be extensive. It has been
shown that the use of a Frisch grid can reduce the effect of the slower carriers in direct x-ray detectors. The
Frisch grid is essentially a conducting grid that shields carriers from the collecting electrode until they are in close
proximity. When the pixel electrodes are properly biased, the grid prevents the slow moving carriers (traveling
away from the collecting electrode) from being collected and puts more weight on the fast moving carriers, thus
allowing the total charge to be collected in less time.
In this paper we investigate the use of a Frisch grid in a-Si:H p-i-n photodetectors for indirect x-ray detectors.
Through simulations and theoretical analysis we determine the grid line sizes and positioning that will be most
effective for practical p-i-n photodetector designs. In addition we compare the results of photodetectors with
and without the grid to characterize the improvement achievable.
Paper Details
Date Published: 22 March 2010
PDF: 9 pages
Proc. SPIE 7622, Medical Imaging 2010: Physics of Medical Imaging, 76223X (22 March 2010); doi: 10.1117/12.844025
Published in SPIE Proceedings Vol. 7622:
Medical Imaging 2010: Physics of Medical Imaging
Ehsan Samei; Norbert J. Pelc, Editor(s)
PDF: 9 pages
Proc. SPIE 7622, Medical Imaging 2010: Physics of Medical Imaging, 76223X (22 March 2010); doi: 10.1117/12.844025
Show Author Affiliations
Nicholas Allec, Univ. of Waterloo (Canada)
Amir H. Goldan, Univ. of Waterloo (Canada)
Kai Wang, Univ. of Waterloo (Canada)
Amir H. Goldan, Univ. of Waterloo (Canada)
Kai Wang, Univ. of Waterloo (Canada)
Published in SPIE Proceedings Vol. 7622:
Medical Imaging 2010: Physics of Medical Imaging
Ehsan Samei; Norbert J. Pelc, Editor(s)
© SPIE. Terms of Use
