A method for the determination of the two-dimensional MTF of digital radiography systems using only the noise response
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

We present a new method that enables the determination of the two-dimensional MTF of digital radiography systems using the noise response measured from flat-field images. Unlike commonly-used methods that measure the onedimensional MTF, this new method does not require precision-made test-objects (slits/edges) or precise tool alignment. Although standard methods are dependent upon data processing that can result in inaccuracies and inconsistencies, this method based on the intrinsic noise response of the imager is highly accurate and less susceptible to such problems. A cascaded-linear-systems analysis was used to derive an exact relationship between the noise power spectrum (NPS) and the presampled MTF of a generalized detector system. The NPS was then used to determine the two-dimensional MTF for three systems: a simulated detector in which the "true" MTF was known exactly, a commercial indirect flat-panel detector (FPD), and a new solid-state x-ray image intensifier (SSXII). For the simulated detector, excellent agreement was observed between the "true" MTF and that determined using the noise response method, with an averaged deviation of 0.3%. The FPD MTF was shown to increase on the diagonals and was measured at 2.5 cycles/mm to be 0.086±0.007, 0.12±0.01, and 0.087±0.007 at 0, 45, and 90°, respectively. No statistically significant variation was observed for the SSXII as a function of angle. Measuring the two-dimensional MTF should lead to more accurate characterization of the detector resolution response, incorporating any potential non-isotropy which may result from the physical characteristics of the sensor, including the active-area shape of the pixel array.

Paper Details

Date Published: 23 March 2010
PDF: 9 pages
Proc. SPIE 7622, Medical Imaging 2010: Physics of Medical Imaging, 76224W (23 March 2010); doi: 10.1117/12.843918
Show Author Affiliations
Andrew Kuhls-Gilcrist, Toshiba Stroke Research Ctr., Univ. at Buffalo (United States)
Daniel R. Bednarek, Toshiba Stroke Research Ctr., Univ. at Buffalo (United States)
Stephen Rudin, Toshiba Stroke Research Ctr., Univ. at Buffalo (United States)


Published in SPIE Proceedings Vol. 7622:
Medical Imaging 2010: Physics of Medical Imaging
Ehsan Samei; Norbert J. Pelc, Editor(s)

© SPIE. Terms of Use
Back to Top