Imaging calibration of thermoacoustic tomography distortion caused by microwave diffraction
Author(s): Liming Nie; Da Xing
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

A uniform energy field of microwave illumination on sample is assumed for microwave-induced thermoacoustic tomography. However, microwave transmitting out of the waveguide surface is nonuniform due to microwave diffraction, which would lead to uneven excitation of thermoacoustic pressure. Hence, the thermoacoustic images may be distorted especially at the edge of microwave radiation. A fast thermoacoustic tomography system at 6 GHz was developed for phantom study and in vivo animals imaging. The effects of microwave distribution inhomogeneity on nonuniform excitation of acoustic pressure were theoretically studied and a corresponding calibration algorithm for image distortion was also provided and experimentally verified. The distribution formulas of microwave field were derived using a Huygens diffraction principle model. Then a point microwave absorber moved under the microwave waveguide to measure the microwave field distribution. The measure data is in good agreement with the deduced result. Once the calibration map was obtained via the theoretical calculation, the TAT (thermoacoustic tomography) images could be calibrated by dividing the reconstructed image by the calibration map. Thermoacoustic images without and with calibration were reconstructed for comparison. According to the statistical results, after calibration the thermoacoustic contrast can be enhanced 2 times or more. Also it can be supposed that the farther the distance away from the illumination centre, the greater signal-noise-ratio (SNR) could be enhanced by the calibration. The results of experiment showed that this method could achieve even distribution of SNR and improve the reconstructed image quality. Therefore, this calibration method has potential application in solving the problem of imaging distortion especially at the edge of microwave illumination.

Paper Details

Date Published: 28 October 2009
PDF: 9 pages
Proc. SPIE 7519, Eighth International Conference on Photonics and Imaging in Biology and Medicine (PIBM 2009), 75190N (28 October 2009); doi: 10.1117/12.843169
Show Author Affiliations
Liming Nie, South China Normal Univ. (China)
Da Xing, South China Normal Univ. (China)


Published in SPIE Proceedings Vol. 7519:
Eighth International Conference on Photonics and Imaging in Biology and Medicine (PIBM 2009)
Qingming Luo; Lihong V. Wang; Valery V. Tuchin; Pengcheng Li; Ling Fu, Editor(s)