Share Email Print
cover

Proceedings Paper

Range performance impact of noise for thermal system modeling
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

This paper presents a comparison of the predictions of NVThermIP to human perception experiment results in the presence of large amounts of noise where the signal to noise ratio is around 1. First, the calculations used in the NVESD imager performance models that deal with sensor noise are described outlining a few errors that appear in the NVThermIP code. A perception experiment is designed to test the range performance predictions of NVThermIP with varying amounts of noise and varying frame rates. NVThermIP is found to overestimate the impact of noise, leading to pessimistic range performance predictions for noisy systems. The perception experiment results are used to find a best fit value of the constant α used to relate system noise to eye noise in the NVESD models. The perception results are also fit to an alternate eye model that handles frame rates below 30Hz and smoothly approaches an accurate prediction of the performance in the presence of static noise. The predictions using the fit data show significantly less error than the predictions from the current model.

Paper Details

Date Published: 22 April 2009
PDF: 12 pages
Proc. SPIE 7300, Infrared Imaging Systems: Design, Analysis, Modeling, and Testing XX, 730004 (22 April 2009); doi: 10.1117/12.817824
Show Author Affiliations
Jonathan D. Fanning, U.S. Army RDECOM CERDEC NVESD (United States)
Brian P. Teaney, U.S. Army RDECOM CERDEC NVESD (United States)
Joseph P. Reynolds, U.S. Army RDECOM CERDEC NVESD (United States)
Todd W. Du Bosq, U.S. Army RDECOM CERDEC NVESD (United States)


Published in SPIE Proceedings Vol. 7300:
Infrared Imaging Systems: Design, Analysis, Modeling, and Testing XX
Gerald C. Holst, Editor(s)

© SPIE. Terms of Use
Back to Top