Share Email Print
cover

Proceedings Paper

Inductosyn angle measuring system error based on AD2S80 resolver-to-digital converter
Author(s): Zhenhuan Wang; Xijun Chen; Ren Li
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

This paper presents an inductosyn angle measurement system based on AD2S80 resolver-to-digital converter. The reason why the reference signal is not orthogonal with the excitation signal is analyzed, and a mathematical model is established for the error. The correctness of the error model is proved by measuring data. The error that the reference signal not be orthogonal with the stimulating magnetism signal causes the quadratic sine harmonic error which has a significant effect on the precision of the angle measurement system.

Paper Details

Date Published: 12 January 2009
PDF: 7 pages
Proc. SPIE 7133, Fifth International Symposium on Instrumentation Science and Technology, 71331B (12 January 2009); doi: 10.1117/12.810456
Show Author Affiliations
Zhenhuan Wang, Harbin Institute of Technology (China)
Xijun Chen, Harbin Institute of Technology (China)
Ren Li, Harbin Institute of Technology (China)


Published in SPIE Proceedings Vol. 7133:
Fifth International Symposium on Instrumentation Science and Technology
Jiubin Tan; Xianfang Wen, Editor(s)

© SPIE. Terms of Use