Hyperspectral image correlation for monitoring membrane protein dynamics in living cells
Author(s): Ryan W. Davis; Bryan Carson; Howland D. T. Jones; Michael B. Sinclair
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Temporal image correlation provides a powerful fluorescence technique for measuring several biologically relevant parameters of molecules in living cells. These parameters include, but are not limited to local concentrations, diffusion dynamics, and aggregation states of biomolecules. However, the complex cellular environment presents several limitations, precluding high quantitative accuracy and constraining biological implementation. In order to address these issues, high speed spectral imaging was employed to compare the results of image correlation from spectrally unmixed and virtually implemented fluorescence emission filters. Of particular interest in this study is the impact of cellular autofluorescence, which is ubiquitous in fluorescence imaging of cells and tissues. Using traditional instrumentation, corrections for autofluorescence are commonly estimated as a static offset collected from a separate control specimen. While this may be sufficient in highly homogenous regions of interest, the low analyte concentrations requisite to fluctuation-based methods result in the potential for unbounded error resulting from spectral cross-talk between local autofluorescence inhomogeneities and the fluorescence signal of interest. Thus we demonstrate the importance of accurate autofluorescence characterization and discuss potential corrections using a case study focusing on fluorescence confocal spectral imaging of immune cells before and after stimulation with lipopolysaccheride (LPS). In these experiments, binding of LPS to the membrane receptor, YFP-TLR4, is observed to result in initiation of the immune response characterized by altered receptor diffusion dynamics and apparent heterogeneous aggregation states. In addition to characterizing errors resulting from autofluorescence spectral bleed-through, we present data leading to a deeper understanding of the molecular dynamics of the immune response and suggest hypotheses for future work utilizing hyperspectrally enabled multi-label fluorescence studies on this system of high biological import.

Paper Details

Date Published: 4 March 2009
PDF: 12 pages
Proc. SPIE 7184, Three-Dimensional and Multidimensional Microscopy: Image Acquisition and Processing XVI, 71840J (4 March 2009); doi: 10.1117/12.807743
Show Author Affiliations
Ryan W. Davis, Sandia National Labs. (United States)
Bryan Carson, Sandia National Labs. (United States)
Howland D. T. Jones, Sandia National Labs. (United States)
Michael B. Sinclair, Sandia National Labs. (United States)


Published in SPIE Proceedings Vol. 7184:
Three-Dimensional and Multidimensional Microscopy: Image Acquisition and Processing XVI
Jose-Angel Conchello; Carol J. Cogswell; Tony Wilson, Editor(s)