Share Email Print
cover

Proceedings Paper

Calibration of prismatic joints in multi-axis machine tools by a three lines measuring method
Author(s): Abdul Wahid Khan; Wuyi Chen
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

A three line calibration method for error quantification in a prismatic joint of a machine tool was proposed and implemented by using a laser interferometer as a working standard. It greatly simplified the measurement setup requirements and accelerated the calibration of prismatic joints. Moreover, it was highly economical by reducing the calibration time and eliminating the use of complex optics. The methodology was implemented on prismatic joints of a three axis CNC machine tool as per standard procedures and guide lines. Cubic spline technique was implemented as error modeling and results obtained were reported for its further use to compensate the errors for improving the accuracy in prismatic joints.

Paper Details

Date Published: 13 October 2008
PDF: 8 pages
Proc. SPIE 7128, Seventh International Symposium on Instrumentation and Control Technology: Measurement Theory and Systems and Aeronautical Equipment, 71281H (13 October 2008); doi: 10.1117/12.806717
Show Author Affiliations
Abdul Wahid Khan, Beihang Univ. (China)
Wuyi Chen, Beihang Univ. (China)


Published in SPIE Proceedings Vol. 7128:
Seventh International Symposium on Instrumentation and Control Technology: Measurement Theory and Systems and Aeronautical Equipment

© SPIE. Terms of Use