Development of an electron-tracking Compton camera based on a gaseous TPC and a scintillation camera for a balloon-borne experiment
Author(s): Kazuki Ueno; Toru Tanimori; Hidetoshi Kubo; Kentaro Miuchi; Shigeto Kabuki; Atsushi Takada; Hironobu Nishimura; Kaori Hattori; Shunsuke Kurosawa; Chihiro Ida; Satoru Iwaki
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

We have developed an Electron-Tracking Compton Camera (ETCC) based on a gaseous micro Time Projection Chamber (ETCC) based on a gaseous micro Time Projection Chamber (μ-TPC) which measures the direction and the energy of the recoil electron and a GSO(Ce) scintillation camera which surrounds the μ-TPC and measures the Compton scattered gamma ray. If not measuring a direction of a recoil electron, a direction of the incident gamma-ray could only be reconstructed as a circle. Measuring the direction of the recoil electron reduces the Compton cone to a point, and thus reconstructs the incident direction completely for a single photon and realizes the strong background rejection. Using the ETCC with a detection volume of about 10cm×10cm×15cm, we had the balloon-borne experiment supported by ISAS/JAXA in 2006 for the purpose of the observation of diffuse cosmic and atmospheric gamma rays. The ETCC obtained about 200 photons with FOV of 3 str in 3 hours in the energy range from 100 keV to 1 MeV, and the obtained flux was consistent with previous observations. On the basis of the results, we are developing the large size ETCC in order to improve the effective area for the next balloon experiment. The large size ETCC has the detection volume of 23cm ×28cm×30cm which consists of the 23cm×28cm×30cm μ-TPC and the 30cm×30cm×1.3cm scintillation camera. Then we obtained the gamma-ray image and investigated the first performances of the large size ETCC. The Angular Resolution Measure (ARM) and the Scatter Plane Deviation (SPD) are 12.1 degree and 117 degree (FWHM) at 662keV, respectively, and the energy resolution is 16.9%(FWHM) at 662keV.

Paper Details

Date Published: 15 July 2008
PDF: 10 pages
Proc. SPIE 7011, Space Telescopes and Instrumentation 2008: Ultraviolet to Gamma Ray, 70113A (15 July 2008); doi: 10.1117/12.789258
Show Author Affiliations
Kazuki Ueno, Kyoto Univ. (Japan)
Toru Tanimori, Kyoto Univ. (Japan)
Hidetoshi Kubo, Kyoto Univ. (Japan)
Kentaro Miuchi, Kyoto Univ. (Japan)
Shigeto Kabuki, Kyoto Univ. (Japan)
Atsushi Takada, ISAS/JAXA (Japan)
Hironobu Nishimura, Kyoto Univ. (Japan)
Kaori Hattori, Kyoto Univ. (Japan)
Shunsuke Kurosawa, Kyoto Univ. (Japan)
Chihiro Ida, Kyoto Univ. (Japan)
Satoru Iwaki, Kyoto Univ. (Japan)


Published in SPIE Proceedings Vol. 7011:
Space Telescopes and Instrumentation 2008: Ultraviolet to Gamma Ray
Martin J. L. Turner; Kathryn A. Flanagan, Editor(s)

© SPIE. Terms of Use
Back to Top