Paper Abstract

Incipient fault diagnosis is closely related to isolation condition assessment. There are a great number of methods available for condition monitoring and diagnosis of power transformer isolation systems, but only few of them can take direct measurements inside the transformer. Fibre optic sensors can be applied to incipient fault diagnosis. In special, acoustic sensors are being developed for the detection and location of partial discharges in oil-filled power transformers. Towards such objective, this work reports investigation on the applicability of fibre Fabry-Pérot interferometers for acoustic detection both in air and in liquids.

Paper Details

Date Published: 16 May 2008
PDF: 4 pages
Proc. SPIE 7004, 19th International Conference on Optical Fibre Sensors, 700441 (16 May 2008); doi: 10.1117/12.786071
Show Author Affiliations
S. E. U. Lima, INESC Porto (Portugal)
Univ. do Porto (Portugal)
O. Frazão, INESC Porto (Portugal)
Univ. do Porto (Portugal)
F. M. Araújo, INESC Porto (Portugal)
L. A. Ferreira, INESC Porto (Portugal)
V. Miranda, INESC Porto (Portugal)
Univ. do Porto (Portugal)
J. L. Santos, INESC Porto (Portugal)
Univ. do Porto (Portugal)


Published in SPIE Proceedings Vol. 7004:
19th International Conference on Optical Fibre Sensors

© SPIE. Terms of Use
Back to Top