Frame-by-frame 3D catheter tracking methods for an inverse geometry cardiac interventional system
Author(s): Michael A. Speidel; Augustus P. Lowell; Joseph A. Heanue; Michael S. Van Lysel
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

The Scanning-Beam Digital X-ray (SBDX) system performs rapid scanning of a narrow x-ray beam using an electronically scanned focal spot and inverse beam geometry. SBDX's ability to perform real-time multi-plane tomosynthesis with high dose efficiency is well-suited to interventional procedures such as left atrial ablation, where precise knowledge of catheter positioning is desired and imaging times are long. We describe and evaluate techniques for frame-by-frame 3D localization of multiple catheter electrodes from the stacks of tomosynthetic images generated by SBDX. The localization algorithms operate on gradient-filtered versions of the tomosynthetic planes. Small high contrast objects are identified by thresholding the stack of images and applying connected component analysis. The 3D coordinate of each object is the center-of-mass of each connected component. Simulated scans of phantoms containing 1-mm platinum spheres were used to evaluate localization performance with the SBDX prototype (5.5 × 5.5 cm detector, 3° tomographic angle) and a with new SBDX detector under design (10-cm wide × 6 cm, 6° × 3°). Z-coordinate error with the SBDX prototype was -0.6 +/- 0.7 mm (mean+/-standard deviation) with 28 cm acrylic, 24.3 kWp source operation, and 12-mm plane spacing. Localization improved to -0.3 +/- 0.3 mm using the wider SBDX detector and a 3-mm plane spacing. The effects of tomographic angle, plane-to-plane spacing, and object velocity are evaluated, and a simulation demonstrating ablation catheter localization within a real anatomic background is presented. Results indicate that SBDX is capable of precise real-time 3D tracking of high contrast objects.

Paper Details

Date Published: 18 March 2008
PDF: 12 pages
Proc. SPIE 6913, Medical Imaging 2008: Physics of Medical Imaging, 69131I (18 March 2008); doi: 10.1117/12.772745
Show Author Affiliations
Michael A. Speidel, Univ. of Wisconsin, Madison (United States)
Augustus P. Lowell, Triple Ring Technologies, Inc. (United States)
Joseph A. Heanue, Triple Ring Technologies, Inc. (United States)
Michael S. Van Lysel, Univ. of Wisconsin, Madison (United States)


Published in SPIE Proceedings Vol. 6913:
Medical Imaging 2008: Physics of Medical Imaging
Jiang Hsieh; Ehsan Samei, Editor(s)