Share Email Print
cover

Proceedings Paper

Exact and approximate cone-beam reconstruction algorithms for C-arm based cone-beam CT using a two-concentric-arc source trajectory
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

In this paper, we present shift-invariant filtered backprojection (FBP) cone-beam image reconstruction algorithms for a cone-beam CT system based on a clinical C-arm gantry. The source trajectory consists of two concentric arcs which is complete in the sense that the Tuy data sufficiency condition is satisfied. This scanning geometry is referred to here as a CC geometry (each arc is shaped like the letter "C"). The challenge for image reconstruction for the CC geometry is that the image volume is not well populated by the familiar doubly measured (DM) lines. Thus, the well-known DM-line based image reconstruction schemes are not appropriate for the CC geometry. Our starting point is a general reconstruction formula developed by Pack and Noo which is not dependent on the existence of DM-lines. For a specific scanning geometry, the filtering lines must be carefully selected to satisfy the Pack-Noo condition for mathematically exact reconstruction. The new points in this paper are summarized here. (1) A mathematically exact cone-beam reconstruction algorithm was formulated for the CC geometry by utilizing the Pack-Noo image reconstruction scheme. One drawback of the developed exact algorithm is that it does not solve the long-object problem. (2) We developed an approximate image reconstruction algorithm by deforming the filtering lines so that the long object problem is solved while the reconstruction accuracy is maintained. (3) In addition to numerical phantom experiments to validate the developed image reconstruction algorithms, we also validate our algorithms using physical phantom experiments on a clinical C-arm system.

Paper Details

Date Published: 18 March 2008
PDF: 12 pages
Proc. SPIE 6913, Medical Imaging 2008: Physics of Medical Imaging, 691321 (18 March 2008); doi: 10.1117/12.772390
Show Author Affiliations
Tingliang Zhuang, Univ. of Wisconsin, Madison (United States)
Joseph Zambelli, Univ. of Wisconsin, Madison (United States)
Brian Nett, Univ. of Wisconsin, Madison (United States)
Shuai Leng, Univ. of Wisconsin, Madison (United States)
Guang-Hong Chen, Univ. of Wisconsin, Madison (United States)


Published in SPIE Proceedings Vol. 6913:
Medical Imaging 2008: Physics of Medical Imaging
Jiang Hsieh; Ehsan Samei, Editor(s)

© SPIE. Terms of Use
Back to Top