Spectral analysis of scattered radiation in CT
Author(s): Klaus J. Engel; Christian Bäumer; Jens Wiegert; Günter Zeitler
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

In the framework of Spectral Computed Tomography (Spectral CT), scattered X-ray radiation is examined for its spectral composition and spatial distribution by means of Monte Carlo simulations. A reliable material (e.g. bone / contrast agent) separation and quantification requires a precise knowledge of the transmitted X-ray spectrum especially for low energy photons. Unfortunately, for lower energies the primary intensity is increasingly covered by scattered radiation. The detected scattered radiation can be classified into two main categories with respect to their scattering history. The first category contains purely Rayleigh or one-time Compton scattered photons which typically have small scattering angles and an energy spectrum similar to that of the transmitted primary radiation. The second category comprises multiple Compton scattered photons with a spectral composition which is typically softer than that of the transmitted primary photons. In regions of strong beam attenuation (i.e. in the X-ray shadow of a scanned object), the scattered radiation is mainly composed of multiple Compton scattered photons. As a consequence, the spectrally resolved scatter-to-primary ratios strongly increase at low energies. High-quality anti-scatter grids can be used to reduce especially the detection of multiple Compton-scattered photons. A quantitative evaluation of measured photon energies below a certain limit between 30 keV and 50 keV (depending on the phantom geometry and the applied anti-scatter grid) is challenging, since primary photons are superposed by a significantly higher amount of scattered photons.

Paper Details

Date Published: 18 March 2008
PDF: 11 pages
Proc. SPIE 6913, Medical Imaging 2008: Physics of Medical Imaging, 69131R (18 March 2008); doi: 10.1117/12.771063
Show Author Affiliations
Klaus J. Engel, Philips Research Europe (Germany)
Christian Bäumer, Philips Research Europe (Germany)
Jens Wiegert, Philips Research Europe (Germany)
Günter Zeitler, Philips Research Europe (Germany)


Published in SPIE Proceedings Vol. 6913:
Medical Imaging 2008: Physics of Medical Imaging
Jiang Hsieh; Ehsan Samei, Editor(s)

© SPIE. Terms of Use
Back to Top