Share Email Print
cover

Proceedings Paper

Accurate measurement of respiratory airway wall thickness in CT images using a signal restoration technique
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Airway wall thickness (AWT) is an important bio-marker for evaluation of pulmonary diseases such as chronic bronchitis, bronchiectasis. While an image-based analysis of the airway tree can provide precise and valuable airway size information, quantitative measurement of AWT in Multidetector-Row Computed Tomography (MDCT) images involves various sources of error and uncertainty. So we have developed an accurate AWT measurement technique for small airways with three-dimensional (3-D) approach. To evaluate performance of these techniques, we used a set of acryl tube phantom was made to mimic small airways to have three different sizes of wall diameter (4.20, 1.79, 1.24 mm) and wall thickness (1.84, 1.22, 0.67 mm). The phantom was imaged with MDCT using standard reconstruction kernel (Sensation 16, Siemens, Erlangen). The pixel size was 0.488 mm × 0.488 mm × 0.75 mm in x, y, and z direction respectively. The images were magnified in 5 times using cubic B-spline interpolation, and line profiles were obtained for each tube. To recover faithful line profile from the blurred images, the line profiles were deconvolved with a point spread kernel of the MDCT which was estimated using the ideal tube profile and image line profile. The inner diameter, outer diameter, and wall thickness of each tube were obtained with full-width-half-maximum (FWHM) method for the line profiles before and after deconvolution processing. Results show that significant improvement was achieved over the conventional FWHM method in the measurement of AWT.

Paper Details

Date Published: 18 March 2008
PDF: 8 pages
Proc. SPIE 6913, Medical Imaging 2008: Physics of Medical Imaging, 691336 (18 March 2008); doi: 10.1117/12.771038
Show Author Affiliations
Sang Joon Park, Seoul National Univ. College of Medicine (South Korea)
Tae Jung Kim, Seoul National Univ. Bundang Hospital (South Korea)
Kwang Gi Kim, National Cancer Ctr. (South Korea)
Sang Ho Lee, Seoul National Univ. College of Medicine (South Korea)
Jin Mo Goo, Seoul National Univ. College of Medicine (South Korea)
Jong Hyo Kim, Seoul National Univ. College of Medicine (South Korea)


Published in SPIE Proceedings Vol. 6913:
Medical Imaging 2008: Physics of Medical Imaging
Jiang Hsieh; Ehsan Samei, Editor(s)

© SPIE. Terms of Use
Back to Top