Correction for source decay in bioluminescence tomography
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Time variation of the bioluminescence source can cause artifacts in the tomographic images. We showed that the a priori knowledge of the light kinetics could be used to eliminate these artifacts. We performed two-dimensional simulations. We considered a 40-mm-diameter circular region with an inclusion of 6-mm-diameter located 10-mm away from the center. The measurement data was simulated using a finite element based forward solver. We modeled the non-contact measurements such that four-wavelength data was collected from four 90-degree-apart views. The results showed that the ratio of the total imaging time to the half-life of the exponentially decaying bioluminescent source was the deciding factor in the reconstruction of the source. It was also demonstrated that a priori knowledge of the source kinetics was required to perform tomographic bioluminescence imaging of short half-life bioluminescent sources and the use of spatial a priori information alone was not adequate.

Paper Details

Date Published: 19 February 2008
PDF: 6 pages
Proc. SPIE 6850, Multimodal Biomedical Imaging III, 685010 (19 February 2008); doi: 10.1117/12.768039