Calibration of an eye oximeter with a dynamic eye phantom
Author(s): A. Nabili; D. Bardakci; K. Helling; C. Matyas; S. Muro; J. C. Ramella-Roman
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Measurements of oxygen saturation and flow in the retina can yield information about the eye health and the onset of eye pathologies such as Diabetic Retinopathy. Recently we have realized an instrument capable of measuring oxygenation in the retina using six different wavelengths and capable of measuring blood flow using speckle-based techniques. The calibration of such instrument is particularly difficult due to the layered structure of the eye and the lack of alternative measurement techniques. For this purpose we have realized an in vitro model of the human eye. The artificial eye is composed of four layers: the retina vessels, the choroids, the retinal pigmented epithelium (RPE), and the sclera. The retina vessels are modeled with 150 μm tube connected to a micro-pump delivering 34 μl/min. The micro-tube, the pump, and a blood reservoir were connected in a closed circulatory system; blood oxygenation in the vessel could be modified using an external oxygen reservoir. The optical properties of all other layers were mimicked using titanium dioxide as a scatterer and ink as an absorber. The absorption coefficient μa and the scattering coefficient µs of these layers were independently measured using an integrating sphere. Absorption and scattering coefficient of all layers were modified before experimental measurements and a Monte Carlo program was finally used to model the experimental results.

Paper Details

Date Published: 21 February 2008
PDF: 10 pages
Proc. SPIE 6870, Design and Performance Validation of Phantoms Used in Conjunction with Optical Measurements of Tissue, 68700N (21 February 2008); doi: 10.1117/12.767556
Show Author Affiliations
A. Nabili, The Catholic Univ. of America (United States)
D. Bardakci, The Catholic Univ. of America (United States)
K. Helling, The Catholic Univ. of America (United States)
C. Matyas, The Catholic Univ. of America (United States)
S. Muro, The Catholic Univ. of America (United States)
J. C. Ramella-Roman, The Catholic Univ. of America (United States)


Published in SPIE Proceedings Vol. 6870:
Design and Performance Validation of Phantoms Used in Conjunction with Optical Measurements of Tissue
Robert J. Nordstrom, Editor(s)

© SPIE. Terms of Use
Back to Top