Share Email Print

Proceedings Paper

Air leak seal for lung dissection plane with diode laser irradiation: monitoring heat-denature with auto-fluorescence
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

We studied the monitoring of heat-denature by autofluorescence spectrum from lung dissection plane during laser air leak sealing procedure. In order to seal the air leakage from lung in thoracotomy, we proposed novel laser sealing method with the combination of the diode laser (810nm wavelength) irradiation and indocyanine green staining (peak absorption wavelength: 805 nm). This sealing method is expected to preserve the postoperative ventilatory capacity and achieve minimally invasive surgery. We previously reported that this laser sealing only requires thin sealing margin (less than 300 μm in thickness) compared with that of the suturing or stapling. The most serious issue on the laser air leak sealing might be re-air-leakage due to rigid surface layer caused by excessive heat-denature, such as carbonization. We should achieve laser air leak sealing minimizing the degree of heat denature. Dissection planes of isolated porcine lung with /without the diode laser irradiation were prepared as samples. We measured the auto-fluorescence from these samples using a spectrometer. When the diode laser was irradiated with 400J/cm2, the surface of diode laser irradiated lung was fully carbonized. The ration of auto-fluorescence emission of 450nm / 500 nm, with 280 nm excitation wavelength was decreased less tha 50 % of initial value. That of 600 nm / 500 nm was increased over 700 % of initial value. The decreasing of the 450 nm auto-fluorescence intensity might be attributed to the heat-denaturing of the interstitial collagen in lung. However, increasing of the 600 nm didn't specify the origins, we suppose it might be originated from heat-denature substance, like carbonization. We could establish the useful monitoring for lung heat-denaturing with simple methodology. We think the auto-fluorescence measurement can be helpful not only for understanding the sealing mechanism, but also for controlling the degree of heat-denaturing during the procedure.

Paper Details

Date Published: 20 February 2008
PDF: 5 pages
Proc. SPIE 6854, Optical Interactions with Tissue and Cells XIX, 685409 (20 February 2008); doi: 10.1117/12.764791
Show Author Affiliations
Maya Gotoh, Keio Univ. (Japan)
Tsunenori Arai, Keio Univ. (Japan)

Published in SPIE Proceedings Vol. 6854:
Optical Interactions with Tissue and Cells XIX
Steven L. Jacques; William P. Roach; Robert J. Thomas, Editor(s)

© SPIE. Terms of Use
Back to Top