Paper Abstract

Phase contrast and interference microscopes are widely used for microbiological and biomedical research. However most of them can't give high precision quantitative estimation of cell volume and morphology due to modest resolution. We propose scheme based on a modified laser Linnik microinterferometer providing high both phase and spatial resolutions. Red blood cell volume is calculated using integration of phase height distribution; limits of integration are determined by Canny edge detection procedure. Experimental volume estimation fits well to volume data obtained with other methods.