Paper Abstract

We have designed, built, and calibrated a transfer radiometer for the VNIR region of the optical spectrum. The instrument is based on a "trap" detector configuration of large-area silicon detectors. The spectral bandpass of the nine bands between about 410 and 1050 nm is set by interference filters. This paper presents the design, characterization, and calibration of the radiometer.

Paper Details

Date Published: 27 September 2007
PDF: 9 pages
Proc. SPIE 6677, Earth Observing Systems XII, 66770W (27 September 2007); doi: 10.1117/12.740231
Show Author Affiliations
Stuart F. Biggar, College of Optical Sciences, The Univ. of Arizona (United States)
Kurtis J. Thome, College of Optical Sciences, The Univ. of Arizona (United States)
Ronald B. Lockwood, Air Force Research Lab. (United States)
Steven Miller, Air Force Research Lab. (United States)


Published in SPIE Proceedings Vol. 6677:
Earth Observing Systems XII
James J. Butler; Jack Xiong, Editor(s)