Share Email Print
cover

Proceedings Paper

Molecular targeting as a contrast agent mechanism for fluorescence endoscopy
Author(s): A. J. Healey; R. Bendiksen; A. Tornes; E. Johannesen
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Several mechanisms of action can be employed for a molecular imaging contrast agent for use with endoscopy. Targeting of cell surface molecules that are up regulated at an early disease stage, with a fluorescent labelled vector is one attractive approach. However, it suffers from the inherent limitation that the concentration of agent available is fundamentally limited by the concentration of receptor molecules available. Simple models indicate that for successful imaging with a targeting approach, the imaging system should be able to adequately image concentrations in the nanomolar region. Such low reporter molecule concentrations have implications for the choice of contrast agent. Target tissue size and location, the tissue native fluorescence contribution, the brightness of the reporter molecule, and photobleaching thresholds are all factors which contribute to the choice of reporter. For endoscopic imaging of millimetre sized target tissue volumes close to the surface Cy5TM (650-700nm) wavelengths are preferable to Cy3TM (550-600nm) and Cy7TM (750-800nm). We have constructed a system optimised for sensitivity by tailoring light delivery, collection, filtering and detection, in order to address the fundamental technical performance limits for endoscopic applications. It is demonstrated through imaging system calibration, phantom based measurement and animal imaging data that low nanomolar concentrations of Cy5 based fluorescent contrast agent in millimetre sized superficial lesions are adequately imaged with a clinically relevant endoscope system in real time. It is concluded that targeting is a technically viable approach for endoscopic applications.

Paper Details

Date Published: 11 July 2007
PDF: 10 pages
Proc. SPIE 6626, Molecular Imaging, 66260F (11 July 2007); doi: 10.1117/12.728261
Show Author Affiliations
A. J. Healey, GE Healthcare Biosciences (Norway)
R. Bendiksen, GE Healthcare Biosciences (Norway)
A. Tornes, GE Healthcare Biosciences (Norway)
E. Johannesen, GE Healthcare Biosciences (Norway)


Published in SPIE Proceedings Vol. 6626:
Molecular Imaging
Kai Licha; Vasilis Ntziachristos, Editor(s)

© SPIE. Terms of Use
Back to Top