Optical methods have many advantages in the beam measurement of particle accelerators. We use transition radiation and Cerenkov Radiation to measure the beam of Dragon-I linear induction accelerator. Beam profile, beam emittance, beam energy and energy dispersion are measured with the help of these radiations.

Paper Details

Date Published: 29 January 2007
PDF: 6 pages
Proc. SPIE 6279, 27th International Congress on High-Speed Photography and Photonics, 62796M (29 January 2007); doi: 10.1117/12.725746
Show Author Affiliations
Guojun Yang, Chinese Academy of Engineering Physics (China)
Zhuo Zhang, Chinese Academy of Engineering Physics (China)
Sifu Chen, Chinese Academy of Engineering Physics (China)