Share Email Print
cover

Proceedings Paper

Research on method of measuring the time of remote explosion point
Author(s): Jianmin Zhou; Hongyan Yin; Kai Xu; Youyu Fu
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

The time when the bomb explodes is one of the most important indexes to appraise the test. According to the principles concerned with explosion radiation, the principle of measuring the time of remote explosion point and composition of measuring system is introduced. Use CCD to record the explosion radiation, DSP to process and record the highcapacity, high-speed video signals, and convert the exploding process examined by floating amplifier into digital signals. Besides, the article analyzes the composing and structural design of the log's optical system, principle of electric control and floating amplifier, dynamic range of the system, power analysis of the incident light, and how to improve the accuracy of measurement in great detail.

Paper Details

Date Published: 11 January 2007
PDF: 6 pages
Proc. SPIE 6279, 27th International Congress on High-Speed Photography and Photonics, 62791Z (11 January 2007); doi: 10.1117/12.725261
Show Author Affiliations
Jianmin Zhou, East China Jiaotong Univ. (China)
Hongyan Yin, East China Jiaotong Univ. (China)
Kai Xu, East China Jiaotong Univ. (China)
Youyu Fu, Changchun Institute of Optics, Fine Mechanics, and Physics (China)


Published in SPIE Proceedings Vol. 6279:
27th International Congress on High-Speed Photography and Photonics

© SPIE. Terms of Use