Paper Abstract

During the last few years, The time resolution of X-ray streak cameras have been improved to near 300-fs. Due to the relative slower sweeping speed and initial energy distribution of electrons, It is hard to breakthrough the 100 fs time resolution barrier. In this letter, time focus and time amplifier system is proposed. The time focus system is used to compensate the time dispersion between photocathode and anode. The using of a time amplifier improves the technical time resolution. The time focus and time amplifier system is designed to a compact fast electrons cavity structure.

Paper Details

Date Published: 11 January 2007
PDF: 8 pages
Proc. SPIE 6279, 27th International Congress on High-Speed Photography and Photonics, 62792I (11 January 2007); doi: 10.1117/12.725255
Show Author Affiliations
J. Liu, Shenzhen Univ. (China)
L. Niu, Shenzhen Univ. (China)
J. Li, Shenzhen Univ. (China)
J. Shi, Shenzhen Univ. (China)
H. Liao, Shenzhen Univ. (China)
W. Peng, Shenzhen Univ. (China)
Q. Yang, Shenzhen Univ. (China)
H. Niu, Shenzhen Univ. (China)


Published in SPIE Proceedings Vol. 6279:
27th International Congress on High-Speed Photography and Photonics
Xun Hou; Wei Zhao; Baoli Yao, Editor(s)