Share Email Print
cover

Proceedings Paper

Image reconstruction and evaluation of system performance for optical fluorescence tomography
Author(s): Tim Nielsen; Bernhard Brendel; Thomas Koehler; Ronny Ziegler; Andy Ziegler; Leon Bakker; Michiel van Beek; Martin van der Mark; Marjolein van der Voort; Rik Harbers; Kai Licha; Martin Pessel; F. Schippers; J. P. Meeuwse; Andrea Feuerabend; Dirk van Pijkeren; Sjaak Deckers
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Diffuse optical tomography is a non-invasive method aiming at the detection of breast cancer. The sensitivity and specificity of the method can be increased if a fluorescent contrast agent is used that accumulates in malignant lesions. Recently, Philips developed an optical scanner, where the patient is lying on a bed, with one breast hanging freely in a cup containing an optical matching fluid. 507 optical fibers are mounted in the surface of the measurement cup. The breast is illuminated sequentially by half of these fibers while the other half is used to collect the light that is emanating from the breast. The system uses near-infrared light of continuous wave solid-state lasers to illuminate the breast at four different wavelengths. A complete measurement takes less than ten minutes and involves five breast scans: transmission data are collected for four wavelengths, and fluorescence data for excitation at one wavelength. Here, we present the image reconstruction scheme and a novel method to assess the system performance in terms of lesion detectability. This method uses a statistical significance test on simulated data with and without a lesion. It allows the quantification of the detectability of lesions for different size, position, or contrast of the lesion. It also allows to analyze the potential impact of system improvements or to judge the performance of an image reconstruction algorithm.

Paper Details

Date Published: 7 February 2007
PDF: 10 pages
Proc. SPIE 6431, Multimodal Biomedical Imaging II, 643108 (7 February 2007); doi: 10.1117/12.715067
Show Author Affiliations
Tim Nielsen, Philips Research Labs. (Germany)
Bernhard Brendel, Philips Research Labs. (Germany)
Thomas Koehler, Philips Research Labs. (Germany)
Ronny Ziegler, Philips Research Labs. (Germany)
Andy Ziegler, Philips Research Labs. (Germany)
Leon Bakker, Philips Research Labs. (Netherlands)
Michiel van Beek, Philips Research Labs. (Netherlands)
Martin van der Mark, Philips Research Labs. (Netherlands)
Marjolein van der Voort, Philips Research Labs. (Netherlands)
Rik Harbers, Philips Research Labs. (Netherlands)
Kai Licha, Bayer Schering Pharma AG (Germany)
Martin Pessel, Bayer Schering Pharma AG (Germany)
F. Schippers, Philips Applied Technologies (Netherlands)
J. P. Meeuwse, Philips Applied Technologies (Netherlands)
Andrea Feuerabend, Philips Design (Netherlands)
Dirk van Pijkeren, Philips Medical Systems (Netherlands)
Sjaak Deckers, Philips Medical Systems (Netherlands)


Published in SPIE Proceedings Vol. 6431:
Multimodal Biomedical Imaging II
Fred S. Azar, Editor(s)

© SPIE. Terms of Use
Back to Top