Large thermal variations can cause significant changes in guided-wave (GW) propagation and transduction for structural health monitoring (SHM). This work focuses on GW SHM using surface-bonded piezoelectric wafer transducers in metallic plates for the temperature range encountered in internal spacecraft structures (20°C to 150°C). First, studies done to determine a suitable bonding agent are documented. That was then used in controlled experiments to examine changes in GW propagation and transduction using PZT-5A piezoelectric wafers under quasi-statically varying temperature (also from 20°C to 150°C). Modeling efforts to explain the experimentally observed increase in time-of-flight and change in sensor response amplitude with increasing temperature are detailed. Finally, these results are used in detection and location of mild and moderate damage using the pulse-echo GW testing approach within the temperature range.

Paper Details

Date Published: 19 April 2007
PDF: 12 pages
Proc. SPIE 6529, Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems 2007, 65290A (19 April 2007); doi: 10.1117/12.715016
Show Author Affiliations
Ajay Raghavan, The Univ. of Michigan (United States)
Carlos E. S. Cesnik, The Univ. of Michigan (United States)


Published in SPIE Proceedings Vol. 6529:
Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems 2007
Masayoshi Tomizuka; Chung-Bang Yun; Victor Giurgiutiu, Editor(s)