Share Email Print
cover

Proceedings Paper

3D view weighted cone-beam backprojection reconstruction for digital tomosynthesis
Author(s): Baojun Li; Gopal Avinash; Bernhard Claus; Stephen Metz
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Cone-beam filtered backprojection (CB-FBP) is one of the major reconstruction algorithms for digital tomosynthesis. In conventional FBP, the photon fluxes in projections are evenly distributed along the X-ray beam. Due to the limited view angles and finite detector dimensions, this uniform weighting causes non-uniformity in the recon images and leads to cone-beam artifact. In this paper, we propose a 3-D view weighting technique in combination with FBP to combat this artifact. An anthropomorphic chest phantom was placed at supine position to enable the imaging of chest PA view. During a linear sweep of X-ray source, 41 X-ray images at different projection angles were acquired with the following protocol: 120kVp, 160mA, and 0.64mAs/exposure. To create the worst scenario for testing, we chose 60 degrees as the sweep angle in this exam. The data set was reconstructed with conventional CB-FBP and proposed algorithm under the same parameters: FOV = 40x40 cm^2, and slice thickness = 4mm. 3 recon slices were randomly selected for review with slice height = 10.5/14.5/17.5cm. Results were assessed qualitatively by human observers and quantitatively through ROI measurement. In each slice, three pre-defined ROIs (50x50 pixels)--ROI A and B are in artifact more pronounced area, and ROI C is in relatively artifact-free area--are extracted and measured. The non-uniformity error was defined as the ratio of MEAN(AVG(C-A), AVG(C-B)) / AVG(C). The average non-uniformity error over the three test images was 0.428 for without view weighting and only 0.041 for with view weighting.

Paper Details

Date Published: 28 March 2007
PDF: 8 pages
Proc. SPIE 6510, Medical Imaging 2007: Physics of Medical Imaging, 65104X (28 March 2007); doi: 10.1117/12.708084
Show Author Affiliations
Baojun Li, General Electric Healthcare (United States)
Gopal Avinash, General Electric Healthcare (United States)
Bernhard Claus, Global Research Ctr., General Electric (United States)
Stephen Metz, General Electric Healthcare (United States)


Published in SPIE Proceedings Vol. 6510:
Medical Imaging 2007: Physics of Medical Imaging
Jiang Hsieh; Michael J. Flynn, Editor(s)

© SPIE. Terms of Use
Back to Top