Paper Abstract

The ion-optical system forming the beam on the entrance of the monopole mass-spectrometer has been proposed. Its general features are the earthing of the emacting electrode to decrease the energy spread in the beam and using of the deflecting system of the untraditional construction (good combining with the axially symmetrical electrodes) which does not let the scattering electrons pass in monopole. The analytical expression of the potential distribution in such deflecting system has been found. The calculation of the ion trajectories has been made by the author program. The parameters of the investigated system and earlier used one in the monopole mass-spectrometer have been compared.

Paper Details

Date Published: 31 May 2006
PDF: 5 pages
Proc. SPIE 6278, Seventh Seminar on Problems of Theoretical and Applied Electron and Ion Optics, 62780D (31 May 2006); doi: 10.1117/12.693195
Show Author Affiliations
T. Ya. Fishkova, Ioffe Physico-Technical Institute (Russia)
L. P. Ovsyannikova, Ioffe Physico-Technical Institute (Russia)
V. A. Surkov, SELMI (Ukraine)