Share Email Print
cover

Proceedings Paper

3D analysis of bone formation around titanium implants using micro-computed tomography (μCT)
Author(s): Ricardo Bernhardt; Dieter Scharnweber; Bert Müller; Felix Beckmann; Jürgen Goebbels; John Jansen; Henning Schliephake; Hartmut Worch
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

The quantitative analysis of bone formation around biofunctionalised metallic implants is an important tool for the further development of implants with higher success rates. This is, nowadays, especially important in cases of additional diseases like diabetes or osteoporosis. Micro computed tomography (μCT), as non-destructive technique, offers the possibility for quantitative three-dimensional recording of bone close to the implant's surface with micrometer resolution, which is the range of the relevant bony structures. Within different animal models using cylindrical and screw-shaped Ti6Al4V implants we have compared visualization and quantitative analysis of newly formed bone by the use of synchrotron-radiation-based CT-systems in comparison with histological findings. The SRμCT experiments were performed at the beamline BW 5 (HASYLAB at DESY, Hamburg, Germany) and at the BAMline (BESSY, Berlin, Germany). For the experiments, PMMA-embedded samples were prepared with diameters of about 8 mm, which contain in the center the implant surrounded by the bony tissue. To (locally) quantify the bone formation, models were developed and optimized. The comparison of the results obtained by SRμCT and histology demonstrates the advantages and disadvantages of both approaches, although the bone formation values for the different biofunctionalized implants are identical within the error bars. SRμCT allows the clear identification of fully mineralized bone around the different titanium implants. As hundreds of virtual slices were easily generated for the individual samples, the quantification and interactive bone detection led to conclusions of high precision and statistical relevance. In this way, SRμCT in combination with interactive data analysis is proven to be more significant with respect to classical histology.

Paper Details

Date Published: 7 September 2006
PDF: 10 pages
Proc. SPIE 6318, Developments in X-Ray Tomography V, 631807 (7 September 2006); doi: 10.1117/12.681000
Show Author Affiliations
Ricardo Bernhardt, Technische Univ. Dresden (Germany)
Dieter Scharnweber, Technische Univ. Dresden (Germany)
Bert Müller, ETH Zürich (Switzerland)
Felix Beckmann, GKSS-Forschungszentrum (Germany)
Jürgen Goebbels, Bundesanstalt für Materialforschung und -prüfung (Germany)
John Jansen, Radboud Univ. Nijmegen (Netherlands)
Henning Schliephake, George-Augusta Univ. (Germany)
Hartmut Worch, Technische Univ. Dresden (Germany)


Published in SPIE Proceedings Vol. 6318:
Developments in X-Ray Tomography V
Ulrich Bonse, Editor(s)

© SPIE. Terms of Use
Back to Top