Share Email Print
cover

Proceedings Paper

Correlation between polymer platform of ArF photoresist and defect in the track nozzle of manufacturing process line
Author(s): Ji Young Song; Dong Chul Seo; Seung Duk Cho; Hyun Sang Joo; Kyoung Mun Kim; Hyun Soon Lim; Sang Jin Kim; Joo Hyeon Park; Jae Chang Jung; Sung Koo Lee; Chul Kyu Bok; Seung Chan Moon
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

As the minimum feature size of electronic devices continues to shrink, the industry is moving from wavelength of 248-nm KrF excimer laser sources to shorter wavelength of 193-nrn ArF excimer laser and ArF immersion to achieve required higher resolution. As minimum feature sizes are reduced, the ability to minimize defects is getting more important, because they have a close connection with yield. With the replacement of laser source, 248-nm with 193-nm, the platform of polymer was also converted from phenolic polymer into acrylic polymer. With this platform changes unexpected various defect problems had been occurred. Although KrF process causes not much of defect, ArF process causes more serious defect problems. One of those major defect source is solidification of polymer in track nozzle. The solidified polymer at track nozzle needs to be removed periodically, unless it causes significant throughput loss in mass production. The amount of this type of defect relies on physical properties of polymer platform such as hydrophilicity, solubility or structural rigidity. The hydrophilic phenol based KrF polymer shows minor defects, contrarily hydrophobic acryl based ArF polymer causes serious defects. The solidification of acrylate type polymer was caused by poor solubility. In order to improve solubility, olefinic moieties such as norbornylene, norbornyl devertives and opened maleic anhydride monomers were adopted in acrylate polymer. Those inserted olefins and opened maleic anhydride in acrylic polymer changed overall structure such as rigid helix structure into flexible structure. With the increase of solubility, particle defect was dramatically reduced. Conclusively, insertion of cycloolefin and opened maleic anhydride moiety releases rigid acrylic structure and it improves solubility. As solubility improves, crystallization at nozzle has been decreased and the particle defect is reduced. Moreover this flexible structure allows the resist reflow at the moderate temperature which is one of the resolution enhancement techniques.

Paper Details

Date Published: 29 March 2006
PDF: 8 pages
Proc. SPIE 6153, Advances in Resist Technology and Processing XXIII, 61533G (29 March 2006); doi: 10.1117/12.657072
Show Author Affiliations
Ji Young Song, Korea Kumho Petrochemical Co., Ltd. (South Korea)
Dong Chul Seo, Korea Kumho Petrochemical Co., Ltd. (South Korea)
Seung Duk Cho, Korea Kumho Petrochemical Co., Ltd. (South Korea)
Hyun Sang Joo, Korea Kumho Petrochemical Co., Ltd. (South Korea)
Kyoung Mun Kim, Korea Kumho Petrochemical Co., Ltd. (South Korea)
Hyun Soon Lim, Korea Kumho Petrochemical Co., Ltd. (South Korea)
Sang Jin Kim, Korea Kumho Petrochemical Co., Ltd. (South Korea)
Joo Hyeon Park, Korea Kumho Petrochemical Co., Ltd. (South Korea)
Jae Chang Jung, Hynix Semiconductor, Inc. (South Korea)
Sung Koo Lee, Hynix Semiconductor, Inc. (South Korea)
Chul Kyu Bok, Hynix Semiconductor, Inc. (South Korea)
Seung Chan Moon, Hynix Semiconductor, Inc. (South Korea)


Published in SPIE Proceedings Vol. 6153:
Advances in Resist Technology and Processing XXIII
Qinghuang Lin, Editor(s)

© SPIE. Terms of Use
Back to Top