Rotating slat collimator design for high-energy near-field imaging
Author(s): Amy Sharma; Carey Floyd; Brian Harrawood; Georgia Tourassi; Anuj Kapadia; Janelle Bender; Joseph Lo; Calvin Howell
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Certain elements (such as Fe, Cu, Zn, etc.) are vital to the body and an imbalance of such elements can either be a symptom or cause of certain pathologies. Neutron Stimulated Emission Computed Tomography (NSECT) is a spectroscopic imaging technique whereby the body is illuminated via a beam of neutrons causing elemental nuclei to become excited and emit characteristic gamma radiation. Acquiring the gamma energy spectra in a tomographic geometry allows reconstruction of elemental concentration images. Previously we have demonstrated the feasibility of NSECT using first generation CT approaches; while successful, the approach does not scale well and has limited resolution. Additionally, current gamma cameras operate in an energy range too low for NSECT imaging. However, the orbiting Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) captures and images gamma rays over the high-energy range equivalent to NSECT's (3 keV to 17 MeV) by utilizing Collimator-based Fourier transform imaging. A High Purity Germanium (HPGe) detector counts the number of energy events per unit of time, providing spectroscopic data. While a pair of rotating collimators placed in front of the detector modulates the number of gamma events, providing spatial information. Knowledge of the number of energy events at each discrete collimator angle allows for 2D image reconstruction. This method has proven successful at a focus of infinity in the RHESSI application. Our goal is to achieve similar results at a reasonable near-field focus. Here we describe the results of our simulations to implement a rotating modulation collimator (RMC) gamma imager for use in NSECT using simulations in Matlab. To determine feasible collimator setups and the stability of the inverse problem a Matlab environment was created that uses the geometry of the system to generate 1D observation data from 2D images and then to reconstruct 2D images using the MLEM algorithm. Reasonable collimator geometries were determined, successful reconstruction was achieved and the inverse problem was found to be stable.

Paper Details

Date Published: 2 March 2006
PDF: 9 pages
Proc. SPIE 6142, Medical Imaging 2006: Physics of Medical Imaging, 614217 (2 March 2006); doi: 10.1117/12.653929
Show Author Affiliations
Amy Sharma, Duke Univ. (United States)
Carey Floyd, Duke Univ. (United States)
Duke Univ. Medical Ctr. (United States)
Brian Harrawood, Duke Univ. Medical Ctr. (United States)
Georgia Tourassi, Duke Univ. Medical Ctr. (United States)
Anuj Kapadia, Duke Univ. (United States)
Janelle Bender, Duke Univ. (United States)
Joseph Lo, Duke Univ. (United States)
Duke Univ. Medical Ctr. (United States)
Calvin Howell, Triangle Univ. Nuclear Lab., Duke Univ. (United States)


Published in SPIE Proceedings Vol. 6142:
Medical Imaging 2006: Physics of Medical Imaging
Michael J. Flynn; Jiang Hsieh, Editor(s)

© SPIE. Terms of Use
Back to Top