Applying a proposed definition for receptor dose to digital projection images
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Digital radiographs are currently characterized in terms of a variety of incompatible, vendor-specific dose metrics, which make it difficult for users to monitor receptor dose. AAPM Task Group #116 has been formed to "Standardize an Image Receptor Dose Index for Digital Radiography," prompting the publication of a proposed definition for receptor dose that can be readily implemented on any system that acquires a projection x-ray image and produces a display-ready image.1 This paper carries that work forward by demonstrating the applicability of that proposal to a range of digital detector types and to a new set of clinical images. Digital receptor dose can be usefully defined for the four ISO beam qualities, in terms of the exposure needed to produce a specified display response in a displayed image, analogous to the ISO speed definition for screen-film images. It requires that the system produce an original image (calibrated in terms of the relationship between system response and exposure for the standard set of x-ray beam qualities defined by ISO-9236-1) and a display-ready image (represented as DICOM GSDF p-values). The receptor dose is computed in terms of the median of pixels in the original image that corresponds to near midrange pixels in the display-ready image. The exposure responses of Gd2O2S-, CsI(Tl)-, a-Se-, and BaFBrI-based digital radiography acquisition systems, as well as a commonly used Gd2O2S screen-film combination, have been measured for the four ISO beam qualities. The proposed receptor dose metric was computed for a sample of 602 clinical images for which body-part thickness technique factors (kV, mAs, and SID) were known. Analysis of this data demonstrates that the proposed receptor dose can be a useful predictor of exposure adequacy over a wide range of body parts and thickness. In conclusion, the proposed vendor-independent receptor dose metric has been shown to produce consistent results across a representative range of digital receptor technologies for a wide range of clinical images. It has also been shown to produce results that are consistent with existing standards for screen-film technology and thereby provides a measurement capable of bridging the transition to digital imaging.

Paper Details

Date Published: 2 March 2006
PDF: 19 pages
Proc. SPIE 6142, Medical Imaging 2006: Physics of Medical Imaging, 614219 (2 March 2006); doi: 10.1117/12.650136
Show Author Affiliations
Richard Van Metter, Eastman Kodak Co. (United States)
John Yorkston, Eastman Kodak Co. (United States)


Published in SPIE Proceedings Vol. 6142:
Medical Imaging 2006: Physics of Medical Imaging
Michael J. Flynn; Jiang Hsieh, Editor(s)

© SPIE. Terms of Use
Back to Top