This paper presents the results of work by Teravicta Technologies to adapt semiconductor industry standards and practices to the qualification of RF MEMS switch components. This includes an overview of parametric test data including contact resistance and key RF performance indicators (insertion loss, return loss, and isolation) and reliability test results, identification of key failure modes, the development of failure accelerants and accelerated life test procedures, and final qualification results. Although some tests are unique to the RF MEMS switch, the methodology presented here provides a sound starting point for the development of qualification procedures for other MEMS devices.