Share Email Print
cover

Proceedings Paper

Optical microsensor for continuous glucose measurements in interstitial fluid
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Tight control of blood glucose levels has been shown to dramatically reduce the long-term complications of diabetes. Current invasive technology for monitoring glucose levels is effective but underutilized by people with diabetes because of the pain of repeated finger-sticks, the inconvenience of handling samples of blood, and the cost of reagent strips. A continuous glucose sensor coupled with an insulin delivery system could provide closed-loop glucose control without the need for discrete sampling or user intervention. We describe an optical glucose microsensor based on absorption spectroscopy in interstitial fluid that can potentially be implanted to provide continuous glucose readings. Light from a GaInAsSb LED in the 2.2-2.4 μm wavelength range is passed through a sample of interstitial fluid and a linear variable filter before being detected by an uncooled, 32-element GaInAsSb detector array. Spectral resolution is provided by the linear variable filter, which has a 10 nm band pass and a center wavelength that varies from 2.18-2.38 μm (4600-4200 cm-1) over the length of the detector array. The sensor assembly is a monolithic design requiring no coupling optics. In the present system, the LED running with 100 mA of drive current delivers 20 nW of power to each of the detector pixels, which have a noise-equivalent-power of 3 pW/Hz1/2. This is sufficient to provide a signal-to-noise ratio of 4500 Hz1/2 under detector-noise limited conditions. This signal-to-noise ratio corresponds to a spectral noise level less than 10 μAU for a five minute integration, which should be sufficient for sub-millimolar glucose detection.

Paper Details

Date Published: 27 February 2006
PDF: 10 pages
Proc. SPIE 6094, Optical Diagnostics and Sensing VI, 609403 (27 February 2006); doi: 10.1117/12.646751
Show Author Affiliations
Jonathon T. Olesberg, Univ. of Iowa (United States)
Chuanshun Cao, Univ. of Iowa (United States)
Jeffrey R. Yager, Univ. of Iowa (United States)
John P. Prineas, Univ. of Iowa (United States)
Chris Coretsopoulos, Univ. of Iowa (United States)
Mark A. Arnold, Univ. of Iowa (United States)
Linda J. Olafsen, Univ. of Kansas (United States)
Michael Santilli, Univ. of Kansas (United States)


Published in SPIE Proceedings Vol. 6094:
Optical Diagnostics and Sensing VI
Gerard L. Coté; Alexander V. Priezzhev, Editor(s)

© SPIE. Terms of Use
Back to Top