Passive ranging of emissive targets using atmospheric oxygen absorption lines
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Highly-energetic targets such as rocket plumes and detonation fireballs are difficult to locate and track effectively with active sensors that rely on reflection, but traditional passive sensors cannot determine range. Development of a passive ranging sensor will enable accurate target location and tracking while simultaneously improving covertness. Recent work is presented on development of a passive sensor to estimate range using spectroscopic measurements of atmospheric absorption. In particular, advantages of measuring absorption on the O 2(bX) transition near 762nm are discussed. Theoretical predictions are compared with experimental results to verify model performance at short ranges (up to 200m). Range accuracy better than 1% has been demonstrated using a Fourier transform spectrometer at short range. Extension of the theory to long range (in excess of 100km) is also discussed.

Paper Details

Date Published: 25 May 2005
PDF: 11 pages
Proc. SPIE 5811, Targets and Backgrounds XI: Characterization and Representation, (25 May 2005); doi: 10.1117/12.604538
Show Author Affiliations
Michael R. Hawks, Air Force Institute of Technology (United States)
Glen P. Perram, Air Force Institute of Technology (United States)


Published in SPIE Proceedings Vol. 5811:
Targets and Backgrounds XI: Characterization and Representation
Wendell R. Watkins; Dieter Clement; William R. Reynolds, Editor(s)

© SPIE. Terms of Use