Flat panel detector-based cone beam CT lung imaging: preliminary system evaluation
Author(s): Ruola Ning; David Conover; Yong Yu; Weixing Cai; Xianghua Lu
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

The purpose of this study is to perform a preliminary evaluation of a newly constructed flat panel detector (FPD)-based system for cone beam CT imaging applications. A prototype flat-panel detector-based cone beam CT imaging system has been designed and constructed by modifying a GE HiSpeed Advantage CT scanner. The prototype consists of a modified GE CT HiSpeed Advantage CT gantry, an x-ray tube, a 397mm x 298mm Varian PaxScan 4030CB real time flat-panel detector mounted on the gantry, a CT table and an on-gantry PC to control image acquisition. Another PC workstation serving as an operating console controls the CT gantry and CT table, and sends trigger pulses to dedicated electronic interface modules to control radiographic exposure and to initiate data acquisition. Captured image data sets are first stored in the on-gantry computer and then downloaded from the on-gantry PC to the operating console for high-speed 3D image reconstruction. During data acquisition, the x-ray tube and the FPD can be rotated on the gantry over Nx360 degrees due to integrated slip ring technology. With a single scan, this device is able to acquire up to three hundred two-dimensional projections (1024 x 768 x 16 bits) for direct 3D reconstruction within 10 seconds. This system was used for a series of preliminary phantom studies and small animal studies. Using the continuous scan mode of the scanner, a few hundred projections were acquired for all volume scans. Direct 3D reconstructions were obtained to evaluate the system for cone beam CT for lung imaging applications. The preliminary results indicate that the newly built flat panel detector-based cone beam CT scanner works as expected and the low contrast resolution of the FPD-based CBCT system is approaching that of a multi-slice CT.

Paper Details

Date Published: 20 April 2005
PDF: 12 pages
Proc. SPIE 5745, Medical Imaging 2005: Physics of Medical Imaging, (20 April 2005); doi: 10.1117/12.596114
Show Author Affiliations
Ruola Ning, Univ. of Rochester Medical Ctr. (United States)
David Conover, Univ. of Rochester Medical Ctr. (United States)
Yong Yu, Univ. of Rochester Medical Ctr. (United States)
Weixing Cai, Univ. of Rochester Medical Ctr. (United States)
Xianghua Lu, Univ. of Rochester Medical Ctr. (United States)


Published in SPIE Proceedings Vol. 5745:
Medical Imaging 2005: Physics of Medical Imaging
Michael J. Flynn, Editor(s)

© SPIE. Terms of Use
Back to Top