Design and development of a fully 3D dedicated x-ray computed mammotomography system
Author(s): Martin P. Tornai; Randolph L. McKinley; Caryl N. Bryzmialkiewicz; Priti Madhav; Spencer J. Cutler; Dominic J. Crotty; James E. Bowsher; Ehsan Samei; Carey E. Floyd
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Our effort to implement a volumetric x-ray computed mammotomography (CmT) system dedicated to imaging breast disease comprises: demonstrated development of a quasi-monochromatic x-ray beam providing minimal dose and other optimal imaging figures of merit; new development of a compact, variable field-of-view, fully-3D acquisition gantry with a digital flat-panel detector facilitating more nearly complete sampling of frequency space and the physical breast volume; incorporation of iterative ordered-subsets transmission (OSTR) image reconstruction allowing modeling of the system matrix. Here, we describe the prototype 3D gantry and demonstrate initial system performance. Data collected on the prototype gantry demonstrate the feasibility of using OSTR with realistic reconstruction times. The gantry consists of a rotating W-anode x-ray tube using ultra-thick K-edge filtration, and an ~20x25cm2 digital flat-panel detector located at <60cm SID. This source/detector combination can be shifted laterally changing the location of the central ray relative to the system center-of-rotation, hence changing the effective imaging field-of-view, and is mounted on a goniometric cradle allowing <50° polar tilt, then on a 360° azimuthal rotation stage. Combined, these stages provide for positioning flexibility in a banded region about a sphere, facilitating simple circle-plus-arc-like trajectories, as well as considerably more complex 3D trajectories. Complex orbits are necessary to avoid physical hindrances from the patient while acquiring the largest imaging volume of the breast. The system capabilities are demonstrated with fully-3D reconstructed images of geometric sampling and resolution phantoms, a fabricated breast phantom containing internal features of interest, and a cadaveric breast specimen. This compact prototype provides flexibility in dedicated, fully-3D CmT imaging of healthy and diseased breasts.

Paper Details

Date Published: 20 April 2005
PDF: 9 pages
Proc. SPIE 5745, Medical Imaging 2005: Physics of Medical Imaging, (20 April 2005); doi: 10.1117/12.595636
Show Author Affiliations
Martin P. Tornai, Duke Univ. Medical Ctr. (United States)
Duke Univ. (United States)
Randolph L. McKinley, Duke Univ. Medical Ctr. (United States)
Duke Univ. (United States)
Caryl N. Bryzmialkiewicz, Duke Univ. Medical Ctr. (United States)
Duke Univ. (United States)
Priti Madhav, Duke Univ. Medical Ctr. (United States)
Duke Univ. (United States)
Spencer J. Cutler, Duke Univ. Medical Ctr. (United States)
Duke Univ. (United States)
Dominic J. Crotty, Duke Univ. Medical Ctr. (United States)
Duke Univ. (United States)
James E. Bowsher, Duke Univ. Medical Ctr. (United States)
Ehsan Samei, Duke Univ. Medical Ctr. (United States)
Duke Univ. (United States)
Carey E. Floyd, Duke Univ. Medical Ctr. (United States)
Duke Univ. (United States)


Published in SPIE Proceedings Vol. 5745:
Medical Imaging 2005: Physics of Medical Imaging
Michael J. Flynn, Editor(s)

© SPIE. Terms of Use
Back to Top