Share Email Print
cover

Proceedings Paper

Quantifying the effect of monitor display settings on observer performance
Author(s): Kent M. Ogden; Adam Oberlander; Walter Huda; Marsha L. Roskopf
Format Member Price Non-Member Price
PDF $17.00 $21.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

A 4-Alternative Forced Choice (4-AFC) experimental paradigm was used to measure observer performance of lesion detection. Each 4-AFC experiment yields a lesion contrast that corresponds to a detection accuracy of 92%, I(92%). Experiments were performed to investigate how imaging performance varied with display level setting (window level) at a constant image contrast (window width). Three observers were used to investigate detection performance with window level using a high quality monitor calibrated three different ways (i.e., DICOM, gamma = 1.5, and gamma = 5.0). There were large inter-observer differences in absolute level of performance, with the detection threshold for the three readers varying by nearly a factor of two. For the DICOM display, the detection threshold was linearly related to image level setting. For one reader, detection performance was independent of level, whereas for the other two readers performance dropped by 30% and 11% over the range of level values investigated. Curves changed from linear for the DICOM display to curvilinear for two gamma monitor display settings. In addition, the absolute level of performance for each reader changed with monitor display setting. When the display gamma was 1.5, observer performance was generally reduced, whereas when the display gamma was 5.0, observer performance was generally better. Our data show that the choice of monitor display is an important parameter that significantly affects lesion detection performance. Adoption of the DICOM display standard will permit the direct inter-comparison of data acquired in different laboratories, as well as clinical practice.

Paper Details

Date Published: 15 April 2005
PDF: 8 pages
Proc. SPIE 5748, Medical Imaging 2005: PACS and Imaging Informatics, (15 April 2005); doi: 10.1117/12.594626
Show Author Affiliations
Kent M. Ogden, Upstate Medical Univ./SUNY (United States)
Adam Oberlander, Upstate Medical Univ./SUNY (United States)
Walter Huda, Upstate Medical Univ./SUNY (United States)
Marsha L. Roskopf, Upstate Medical Univ./SUNY (United States)


Published in SPIE Proceedings Vol. 5748:
Medical Imaging 2005: PACS and Imaging Informatics
Osman M. Ratib; Steven C. Horii, Editor(s)

© SPIE. Terms of Use