Share Email Print
cover

Proceedings Paper

Directional volume growing for the extraction of white matter tracts from diffusion tensor data
Author(s): D. Merhof; P. Hastreiter; C. Nimsky; R. Fahlbusch; G. Greiner
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Diffusion tensor imaging measures diffusion of water in tissue. Within structured tissue, such as neural fiber tracts of the human brain, anisotropic diffusion is observed since the cell membranes of the long cylindric nerves restrict diffusion. Diffusion tensor imaging thus provides information about neural fiber tracts within the human brain which is of major interest for neurosurgery. However, the visualization is a challenging task due to noise and limited resolution of the data. A common visualization strategy of white matter is fiber tracking which utilizes techniques known from flow visualization. The resulting streamlines provide a good impression of the spatial relation of fibers and anatomy. Therefore, they are a valuable supplement for neurosurgical planning. As a drawback, fibers may diverge from the exact path due to numerical inaccuracies during streamline propagation even if higher order integration is used. To overcome this problem, a novel strategy for directional volume growing is presented which enables the extraction of separate tract systems and thus allows to compare and estimate the quality of fiber tracking algorithms. Furthermore, the presented approach is suited to get a more precise representation of the volume encompassing white matter tracts. Thereby, the entire volume potentially containing fibers is provided in contrast to fiber tracking which only shows a more restricted representation of the actual volume of interest. This is of major importance in brain tumor cases where white matter tracts are in the close vicinity of brain tumors. Overall, the presented strategy contributes to make surgical planning safer and more reliable.

Paper Details

Date Published: 12 April 2005
PDF: 8 pages
Proc. SPIE 5744, Medical Imaging 2005: Visualization, Image-Guided Procedures, and Display, (12 April 2005); doi: 10.1117/12.594621
Show Author Affiliations
D. Merhof, Univ. of Erlangen-Nuremberg (Germany)
P. Hastreiter, Univ. of Erlangen-Nuremberg (Germany)
C. Nimsky, Univ. of Erlangen-Nuremberg (Germany)
R. Fahlbusch, Univ. of Erlangen-Nuremberg (Germany)
G. Greiner, Univ. of Erlangen-Nuremberg (Germany)


Published in SPIE Proceedings Vol. 5744:
Medical Imaging 2005: Visualization, Image-Guided Procedures, and Display
Robert L. Galloway; Kevin R. Cleary, Editor(s)

© SPIE. Terms of Use
Back to Top