Medical linear accelerator x-ray sources: variation with make, model, and time
Author(s): David A. Jaffray; Jerry J. Battista; Aaron Fenster; Peter Munro
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

One difficulty in radiation therapy is ensuring the correct placement of the radiation field so that the radiation is delivered to the diseased regions while healthy tissues are spared. Currently, field placement is assessed by producing a transmission radiograph (portal image) using the high-energy treatment beam. Often the quality of these images is poor. One factor which influences image quality is the size of the x-ray source found in medical linear accelerators. These sources can be large and thus reduce the spatial resolution of the portal images, thereby reducing our ability to detect bony anatomical landmarks. The high energy of the x rays generated in these accelerators make it impossible to measure the x-ray source using standard techniques (e.g., pin-hole camera or star-patterns). We have developed a reconstruction technique which allows quantitative measurement of these sources. Using this technique, we have investigated and compared the size and shape of x-ray sources on a total of seven accelerators. These include: (1) two Varian Clinac 2100cs, (2) two Atomic Energy of Canada Ltd. (AECL) Therac 6s, (3) a Varian Clinac 600c, (4) an AECL Therac 25, and (5) a Therac 20. The comparisons also include monitoring the size and shape of the sources over a two year period. For each of these measured sources the source MTF has been calculated at typical magnifications. It has been found that (1) the size and shape of the source spot varies greatly between accelerators of different design; (2) for accelerators of the same design, however, the source spots were similar; and (3) the spatial resolution of currently available on-line verification imaging systems is only marginally reduced by the size and shape these source spots.

Paper Details

Date Published: 1 June 1992
PDF: 8 pages
Proc. SPIE 1651, Medical Imaging VI: Instrumentation, (1 June 1992); doi: 10.1117/12.59395
Show Author Affiliations
David A. Jaffray, Univ. of Western Ontario and London Regional Cancer Ctr. (Canada)
Jerry J. Battista, Univ. of Western Ontario and London Regional Cancer Ctr. (Canada)
Aaron Fenster, Univ. of Western Ontario and John P. Robarts Research Institute (Canada)
Peter Munro, Univ. of Western Ontario and London Regional Cancer Ctr. (Canada)


Published in SPIE Proceedings Vol. 1651:
Medical Imaging VI: Instrumentation
Rodney Shaw, Editor(s)

© SPIE. Terms of Use
Back to Top