The feasibility of using X-ray fluorescence techniques to determine the concentration of silver, bromine, and iodine in silver halide holographic films is studied. A small apparatus employing a 30 mCi 57Co radioactive source and a Germanium photon detector is described. AgBr - films were exposed to different amounts of light and subjected to several types of chemical processing, and their silver and halide content were investigated. In addition the relation between the concentration of absorbing silver in the emulsion and optical density was determined.

Paper Details

Date Published: 1 January 1992
PDF: 9 pages
Proc. SPIE 1600, Intl Symp on Display Holography, (1 January 1992); doi: 10.1117/12.57767
Show Author Affiliations
Juergen P. Eichler, Technische Fachhochschule (Germany)
Gerhard K. Ackermann, Technische Fachhochschule (Germany)
H. E. Wolf, Univ. Federal Fluminense (Brazil)